Command Group: Checkweigher | Access: | Network interfaces: | |
| RW | CANopen | SDO2100sub0E |
| | MODbus | 2412,2 |
SD - Start Delay (0-65535ms) | | PROFIbus | read 18,14 write 31,14 |
Synopsis: |
| Command | Response |
Get | SD | S<Value> |
Set | SD <Value> | OK (or ERR) |
|
Valid for | Min. value | Max. value |
141.181 |
0 |
500 |
141.185 |
0 |
500 |
141.186 |
0 |
500 |
142.181 |
0 |
500 |
142.185 |
0 |
500 |
142.186 |
0 |
500 |
143.181 |
0 |
65535 |
143.185 |
0 |
65535 |
151.181 |
0 |
65535 |
151.184 |
0 |
65535 |
151.186 |
0 |
65535 |
152.181 |
0 |
65535 |
152.184 |
0 |
65535 |
162.181 |
0 |
65535 |
179.181 |
0 |
65535 |
181.181 |
0 |
65535 |
64.181 |
0 |
65535 |
68.181 |
0 |
500 |
72.181 |
0 |
500 |
78.183 |
0 |
65535 |
88.183 |
0 |
65535 |
|
SD Set the delay between falling/rising edge of trigger pulse and start of measurement.
See also
MT,
GA,
SA,
TE,
TR,
TL