PL2

Flow Scale

PL2


Command Group: MassFlow

Access:

Network interfaces:

RW

CANopen

SDO2B00sub02

MODbus

2502,2

PL2 - Set the flow scale

PROFIbus

read 42,2 write 42,130


Synopsis:
CommandResponse
GetPL2P2:<Value>
SetPL2 <Value>OK (or ERR)
Valid forMin. valueMax. value
141.185 0 8
142.185 0 8
143.185 0 8
88.185 0 8



PL2 Flow Time Scale

Select Loss-In-Weight / Mass Flow rate (weight unit / time unit).
The following rates units are available:

For the DAD141/DAD142 using Firmware 1.60 and later, this command defines the time scaling of the weight / mass flow rate, which means delta weight per time unit.
The following scalings are available:

See also  LS, LI, GF, GR, GM, PL1, PL3, PL4, PL5.
And for the DAD:  VF, GD, PL6, PL7, PL8, PL9, PL10, PL11, PL12, PL13, PL14, PL15, PL16, PL17, PL18, PL19, PL20, PL21.