PL14

Refill Timeout

PL14


Command Group: MassFlow

Access:

Network interfaces:

RW

CANopen

SDO2B00sub0E

MODbus

251A,2

PL14 - Refill_Timeout

PROFIbus

read 42,14 write 42,142


Synopsis:
CommandResponse
GetPL14P14:<Value>
SetPL14 <Value>OK (or ERR)
Valid forMin. valueMax. value
141.185 0 999999
142.185 0 999999
143.185 0 999999



PL14 Refill timeout

This timeout period starts at the beginning of a refill period and if the refilling is not completed before the timeout then an error will be flagged.
Refill timeout PL14 will be setup in 10ms per increment.

Available setup range: 0 to 999999. A value of zero will disable this function.

See also  LS, LI, GF, GR, GM, PL1, PL2, PL3, PL4, PL5.
And for the DAD:  VF, GD, PL6, PL7, PL8, PL9, PL10, PL11, PL12, PL13, PL15, PL16, PL17, PL18, PL19, PL20, PL21, and AA