PL13

Volumetric Start

PL13


Command Group: MassFlow

Access:

Network interfaces:

RW

CANopen

SDO2B00sub0D

MODbus

2518,2

PL13 - Volumetric Start

PROFIbus

read 42,13 write 42,141


Synopsis:
CommandResponse
GetPL13P13:<Value>
SetPL13 <Value>OK (or ERR)
Valid forMin. valueMax. value
141.185 0 100
142.185 0 100
143.185 0 100



PL13 Set Analog Output (for volumetric dosing)

With this command, the analog output is set to a static value, e.g. to 50%. Hereby a static analog value may be set for the starting phase of a ‘Loss in weight’ application, which serves the feeder as input controlled variable. This setting remains active as long as no material removal takes place. As soon as a decrease in the material net weight is detected, the PID controller automatically assumes control of the analogue output depending on the material flow.

Setup range: 1 to 100%.

See also  LS, LI, GF, GR, GM, PL1, PL2, PL3, PL4, PL5.
And for the DAD:  VF, GD, PL6, PL7, PL8, PL9, PL10, PL11, PL12, PL14, PL15, PL16, PL17, PL18, PL19, PL20, PL21, and AA