PL12

NMT_Flow

PL12


Command Group: MassFlow

Access:

Network interfaces:

RW

CANopen

SDO2B00sub0C

MODbus

2516,2

PL12 - NMT_Flow

PROFIbus

read 42,12 write 42,140


Synopsis:
CommandResponse
GetPL12P12:<Value>
SetPL12 <Value>OK (or ERR)
Valid forMin. valueMax. value
141.185 0 65535
142.185 0 65535
143.185 0 65535



PL12 No motion time - flow

The mass flow change detection provides a means for "freezing" the analog output whenever an instability condition or "change" is detected.
The condition "no change" or "stable state" is reached when the measurement signal for the time set in PL12 is stable and during this time does not fluctuate more than the "allowed" change range set in PL11.
The time set in PL12 is defined as PL12 x Δt where Δt is defined by PL3.

Setup range: 1 to 65535.

See also  LS, LI, GF, GR, GM, PL1, PL2, PL3, PL4, PL5.
And for the DAD:  VF, GD, PL6, PL7, PL8, PL9, PL10, PL11, PL13, PL14, PL15, PL16, PL17, PL18, PL19, PL20, PL21, and AA