LS

Loss Control

LS


Command Group: MassFlow

Access:

Network interfaces:

RW

CANopen

SDO2C00sub01

MODbus

2600,1

LC - Controls the mass flow measurement

PROFIbus

read 41,1 write 41,129


Synopsis:
CommandResponse
GetLSC:<Value>
SetLS <Value>OK (or ERR)
Valid forMin. valueMax. value
141.185 0 255
142.185 0 255
143.185 0 255
88.185 0 255



LS Mass flow control

The LS command is used for starting, stopping and freezing the process from the host controller.

For the LDM88:
The lower bits (0..3) are set by the PLC to indicate a ‘Start/Stop’ signal outputs 0..3. Bit 4 is set by the PLC to indicate a ‘Start/Stop’ signal. Bit 5 is set by the PLC to indicate ‘Flow Frozen’, for example whilst the shaking process is carried out.

For the DAD141 and DAD142:
Mass flow control values:

See also  LS, LI, GF, GR, GM, PL1, PL2, PL3, PL4, PL5.
And for the DAD:  VF, GD, PL6, PL7, PL8, PL9, PL10, PL11, PL12, PL13, PL14, PL15, PL16, PL17, PL18, PL19, PL20, and PL21.