AH

Set Analog High

AH


Command Group: Analog

Access:

Network interfaces:

RW

CANopen

SDO2100sub02

MODbus

2102,2

AH - Set the analog high level

PROFIbus

read 18,2 write 31,2


Synopsis:
CommandResponse
GetAHH<Value>
SetAH <Value>OK (or ERR)
Valid forMin. valueMax. value
141.181 -999999 999999
141.184 -999999 999999
141.185 -999999 999999
141.186 -999999 999999
142.181 -999999 999999
142.184 -999999 999999
142.185 -999999 999999
142.186 -999999 999999
143.181 -999999 999999
143.184 -999999 999999
143.185 -999999 999999
72.181 0 99999
72.184 0 99999



AH Set the analog high level. This command defines the weight value for 20mA analog output. Issuing the AH command without any parameters will return the current high level value in the form H+10000.
Factory default setting: 10000.

See also AA, AL, AM. AS.